ARA-290 10 mg
Erythropoietin-derived 11-mer studied in tissue-protective and neuropathy models.
In stock · ships same day on orders before 2pm ET
| Quantity | Per unit | You save |
|---|---|---|
| 3 to 4 units | $76.26 | 7% |
| 5 to 9 units | $72.98 | 11% |
| 10+ units | $68.88 | 16% |
Verify lot ARA-2609-X in the COA library · This month's lot report
Ships same day on orders before 2pm ET. For laboratory research use only. Not for human or animal consumption.
Supplies researchers add to this order


What is ARA-290?
ARA-290, also called cibinetide, is an 11-amino-acid peptide derived from the helix B domain of erythropoietin. It binds the innate repair receptor without the haematopoietic activity of the parent hormone, which is the point of the fragment: tissue-protective signalling can be studied without the erythropoietic confound. Pepstral supplies it as a lyophilized powder for in-vitro laboratory research only.
What is ARA-290 studied for?
- Innate repair receptor binding assays
- Neuropathy and small-fibre models
- Tissue-protection studies
- Erythropoietin fragment comparisons
All applications above are in-vitro or preclinical research contexts. ARA-290 is sold for laboratory research only and is not for human or animal use.
What does the certificate for lot ARA-2609-X show?
Every lot of ARA-290 is tested by an independent US laboratory before it is listed. The report for lot ARA-2609-X is in the COA library and the lot number printed on the vial matches it. The current results:
| Test | Method | Lot ARA-2609-X result |
|---|---|---|
| Identity | LC-MS | Matches the calculated mass for the sequence |
| Purity | HPLC-UV, 220 nm | 99.0% |
| Net peptide content | Amino acid analysis | Stated per vial on the certificate |
| Endotoxin | LAL, chromogenic | < 0.5 EU/mg |
| Sterility | USP <71> | Pass |
How is ARA-290 handled and stored?
Sealed vials are stored at -20°C away from light and keep for 24 months. To reconstitute, add bacteriostatic water slowly down the inside wall of the vial and swirl until clear; never shake. Once in solution, keep at 2 to 8°C and use within the 28-day window on the certificate. The reconstitution guide covers volumes and syringe units and the concentration table gives the numbers for this vial.
Frequently asked questions
Does ARA-290 raise red cell counts?
No. It was designed to engage the innate repair receptor without the erythropoietin receptor activity that drives haematopoiesis, which is why it is used where that confound matters.
What is the innate repair receptor?
A heteromer of the erythropoietin receptor and the beta-common receptor, distinct from the homodimeric receptor that drives red cell production.
Is ARA-290 for human use?
No. Every product on this site is sold for in-vitro laboratory research only and is not for human or animal consumption, diagnostic or therapeutic use.